Centralized motor control for plants that can't afford downtime — custom-built, IP65-rated, and compatible with DOL, Star-Delta, Soft Starter & VFD configurations.









Standard configuration shown below every panel is custom-built to your load, environment, and compliance requirements
Electrical Ratings
Rated Voltage | Nominal voltage at which the MCC operates | 230 / 415 / 690V AC |
Frequency | Operating frequency of the MCC | 50 / 60 Hz |
Rated Current | Maximum current the MCC can handle | 100A - 6300A |
Short Circuit Withstand (Icw) | Maximum current withstood during a short circuit | 25 kA - 100 kA |
Control Voltage | Voltage used for control circuits | 24V DC / 110V AC/DC / 230V AC |
Protection & Safety
Ingress Protection | Protection level against dust and water | IP 42 / 54 / 55 / 65 |
Protection Relays | Types of protection relays provided | Overload, SC, Earth Fault, U/O Voltage |
Compliance Standards | Standards to which the MCC conforms | IEC 61439, IS 8623, NEMA |
Earthing | Provision for earthing | Copper / Aluminum Earthing Bus |
Construction
Number of Starters | Total motor starters housed in the MCC | 1 - 48 |
Type of Starters | Type of motor starters provided | DOL, Star-Delta, Soft Starter, VFD |
Busbar Material | Material used for busbars | Electrolytic Grade Copper / Aluminum |
Busbar Size | Cross-sectional area of the busbar | 25x5mm - 100x10mm |
Busbar Insulation | Insulation type for the busbar | Heat Shrink PVC / Epoxy Coated |
Panel Structure | Type of structure used | Fixed / Compartmentalized / Drawout |
Panel Color | Color of the panel's external surface | RAL 7032 / 7035 / Custom |
Cable Entry | Provision for cable entry | Bottom / Top |
Environmental
Operating Temperature | Ambient temperature range for normal operation | -25°C to +55°C |
Cooling Arrangement | Method used for cooling the panel | Natural / Forced Air Cooling |
Auxiliary Power Supply | Power supply for auxiliary circuits | 24V DC / 48V DC / 230V AC |
Engineering discipline, compliance-first manufacturing, and configurations built around your actual operationnot a catalog SKU.
Every panel built in-house to spec, not assembled from third-party kits.
IEC 61439 / UL 845 / NEMA built into the design process, not retrofitted.
The same engineering team builds your MCC, PCC, PLC, AMF, and distribution panels one vendor for your full electrical room. See all panel types →
No reseller markup, no communication layers between you and the people building your panel
IEC 61439, UL 845, and NEMA compliance isn't a checkbox for us — it's built into the panel from the first drawing
Every industry has different load profiles, environments, and compliance demands — our panels are configured accordingly.
Real feedback from plant owners, EPCs, and engineers who've specified Burak Electric panels for critical operations.
Reliable panels and excellent technical support throughout the project
Good quality MCC panels delivered on time with proper testing.
Professional team, smooth execution, and great after-sales service
A Motor Control Center panel widely known as a MCC panel is a single enclosure that houses multiple motor starters, circuit breakers, and control devices, allowing centralized starting, monitoring, and protection, of electric motors across a facility from one location. As a category of industrial control panel motor equipment, the MCC sits at the center of any plant's motor control systems.
Motors fail without warning when starters are scattered, unmonitored, and disconnected from a single point of diagnostics
Older or unbranded panels fail IEC/UL audits during plant expansion, insurance review, or client inspection.
Facility and motor count grow, but a non-modular panel means a full rebuild instead of an extension.
Inadequate IP rating or fault protection in dusty, wet, or chemical-heavy environments puts personnel at risk.
One centralized, compliant motor control center replaces fragmented starters scattered across a plant floor and becomes the backbone of facility uptime. Standardized protection, a single point of monitoring, and predictable maintenance all flow from this one structural decision.
That's why MCC panels are treated as long-term infrastructure by serious industrial buyers not a line-item commodity purchase to be sourced on price alone.
Built for the operating conditions of real industrial environments not just the test bench.
Intelligent Motor Management (SIMOCODE-compatible): Real-time motor diagnostics that flag a failing motor before it trips the line turning reactive maintenance into planned maintenance.
Custom-Configured, Not Off-the-Shelf: Starter type, IP rating, and busbar sizing matched to your exact load and environment.
Built to Scale: Modular compartment design means adding starters later doesn't mean rebuilding the panel.
Advanced Monitoring: Live visibility into motor performance, reducing reactive maintenance and emergency callouts.
Cross-Industry Versatility: Same engineering discipline whether the application is manufacturing, water treatment, or HVAC
From incoming power to motor protection the control path inside every Burak Electric MCC.
Incoming power enters via the bus chamber (copper busbar distribution).
Power routes to starter compartments DOL, Star-Delta, Soft Starter, or VFD.
Protection relays monitor each motor circuit for overload, short circuit, and earth fault independently.
Control voltage circuits handle start/stop logic and interlocking.
SIMOCODE monitoring reports real-time status, optionally integrating with plant SCADA
Fewer surprises. Faster diagnostics. A panel that's still right for you after you scale.
Every panel goes through structured quality checks before it ships.
Connect With Us, We're Here to Help
Unlock the Burak Electric advantage—precision, innovation, and excellence in every electrical control panel. Start your success with a quote today!